Siemens Simcenter Femap

View CSAF Summary Simcenter Femap is affected by an out of bounds read vulnerability that could be triggered when the application reads files in X_T format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released a new version for Simcenter Femap and recommends to update to the latest version.

The following versions of Siemens Simcenter Femap are affected: Simcenter Femap vers:intdot/<2606.0002 (CVE-2026-64629) CVSS Vendor Equipment v3 7.8 Siemens Simcenter Femap 1 Vulnerability Out-of-bounds Read Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities CVE-2026-64629 The affected applications contains an out of bounds read vulnerability while parsing specially crafted X_T files.

This could allow an attacker to execute code in the context of the current process. Read More 1 Affected Product Simcenter Femap < V2606.

The following versions of Siemens Simcenter Femap are affected: Simcenter Femap vers:intdot/<2606.0002 (CVE-2026-64629) CVSS Vendor Equipment v3 7.

1 Affected Product Simcenter Femap < V2606.0002 Product Status: known_affected Remediations Vendor fix Update to V2606.0002 or later version Additional Metrics Relevant CWE: CWE-125 Out-of-bounds Read CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H View CVE Details Acknowledgments Siemens ProductCERT reported this vulnerability to CISA.

General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms.

In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: and to follow the recommendations in the product manuals.